Gas valve selection criteria
Gas valve selection criteria are as follows :
1 , the spring pressure at a given level within the outlet pressure between the maximum and minimum values can be continuously adjusted , without jamming and abnormal vibration ;
2, for the soft seal valve , within a specified period of time may not have leakage ; For metal seal valve, its leakage should not exceed 0.5% of the maximum flow ;
3, the outlet flow rate change , the direct -acting outlet pressure deviation is not greater than 20% , not more than 10% of the pilot ;
4, the inlet pressure changes, the direct-acting outlet pressure deviation is less than 10% of the pilot less than 5% ;
5 , in general, the pressure reducing valve valve valve before the pressure should be less than 0.5 times ;
6, the valve very wide range of applications , in the steam , compressed air, industrial gas , water, oil, and many other devices and the tube the liquid medium can be used on the road , the medium flows through the valve at the outlet amount of the general with a mass flow or volume flow representation ;
7 , bellows direct-acting pressure reducing valves for low , medium and small caliber steam medium ;
8 , the film direct-acting pressure reducing valves for low-voltage , medium -caliber air, water medium ;
9 , the pilot piston valve , suitable for all kinds of pressure , of various calibres , a variety of temperature steam , air and water medium ,
If using acid-resistant stainless steel, suitable for a variety of corrosive media ;
10 , the pilot valve bellows , suitable for low voltage , medium and small caliber steam, air and other media ;
11 , the pilot valve membrane is suitable for low, medium , small and medium -caliber steam or water and other media ;
12 , relief valve inlet pressure fluctuation should be controlled at a given inlet pressure value of 80% to 105% , if more than this range, decompression early performance suffers ;
13 , usually after the pressure reducing valve valve valve before the pressure should be less than 0.5 times ;
14 , valve springs only every file in a certain outlet pressure range applies beyond the scope should replace the spring ;
15 , in the medium temperature is relatively high occasions , generally used in pilot piston bellows valve or pilot valve ;
16 , the medium is air or water ( liquid ) of the occasion, the general should use direct acting diaphragm type pressure reducing valve or pilot film ;
17 , the medium is steam occasions , should use the pilot or pilot piston bellows valve ;